Objective. To enable practical interferometry-based phase contrast CT using standard incoherent x-ray sources, we propose an imaging system where the analyzer grating is replaced by a highresolution detector. Since there is no need to perform multiple exposures (with the analyzer grating at different positions) at each scan angle, this scheme is compatible with continuous-rotation CT apparatus, and has the potential to reduce patient radiation dose and patient motion artifacts. Approach. Grating-based x-ray interferometry is a well-studied technique for imaging soft tissues and highly scattering objects embedded in such tissues. In addition to the traditional x-ray absorptionbased image, this technique allows reconstruction of the object phase and small-angle scattering information. When using conventional incoherent, polychromatic, hard x-ray tubes as sources, three gratings are usually employed. To sufficiently resolve the pattern generated in these interferometers with contemporary x-ray detectors, an analyzer grating is used, and consequently multiple images need to be acquired for each view angle. This adds complexity to the imaging system, slows image acquisition and thus increases sensitivity to patient motion, and is not dose efficient. By simulating image formation based on wave propagation, and proposing a novel phase retrieval algorithm based on a virtual grating, we assess the potential of a analyzer-grating-free system to overcome these limitations. Main results.Wedemonstrate that the removal of the analyzer-grating can produce equal image contrast-to-noise ratio at reduced dose (by a factor of 5), without prolonging scan duration. Significance. By demonstrating that an analyzer-free CT system, in conjuction with an efficient phase retrieval algorithm, can overcome the prohibitive dose and workflow penalties associated gratingstepping, an alternative path towards realizing clinical inteferometric CT appears possible....
High performance X-ray detector with ultra-high spatial and temporal resolution are crucial for biomedical imaging. This study reports a dynamic directconversion CMOS X-ray detector assembled with screen-printed CsPbBr3, whose mobility-lifetime product is 5.2 × 10−4 cm2 V–1 and X-ray sensitivity is 1.6 × 104 μC Gyair –1 cm–2. Samples larger than 5 cm× 10 cm can be rapidly imaged by scanning this detector at a speed of 300 frames per second along the vertical and horizontal directions. In comparison to traditional indirectconversion CMOS X-ray detector, this perovskite CMOS detector offers high spatial resolution (5.0 lpmm−1) X-ray radiographic imaging capability at low radiation dose (260 nGy). Moreover, 3D tomographic images of a biological specimen are also successfully reconstructed. These results highlight the perovskite CMOS detector’s potential in high-resolution, large-area, low-dose dynamic biomedical X-ray and CT imaging, as well as in non-destructive X-ray testing and security scanning....
AT2018cow is the most extensively observed and widely studied fast blue optical transient to date; its unique observational properties challenge all existing standard models. In this paper, we model the luminosity evolution of the optical, soft X-ray, and hard X-ray emission, as well as the X-ray spectrum of AT2018cow with a magnetarcentered engine model. We consider a two-zone model with a striped magnetar wind in the interior and an expanding ejecta outside. The soft and hard X-ray emission of AT2018cow can be explained by the leakage of high-energy photons produced by internal gradual magnetic dissipation in the striped magnetar wind, while the luminous thermal UV/optical emission results from the thermalization of the ejecta by the captured photons. The two-component energy spectrum yielded by our model with a quasi-thermal component from the optically thick region of the wind superimposed on an optically thin synchrotron component well reproduces the X-ray spectral shape of AT2018cow. The Markov Chain Monte Carlo fitting results suggest that in order to explain the very short rise time to peak of the thermal optical emission, a low ejecta mass Mej ≈ 0.1Me and high ejecta velocity vSN » 0.17c are required. A millisecond magnetar with P0 ≈ 3.7 ms and Bp ≈ 2.4 × 1014 G is needed to serve as the central engine of AT2018cow....
X-ray binary systems consist of a companion star and a compact object in close orbit. Thanks to their copious X-ray emission, these objects have been studied in detail using X-ray spectroscopy and timing. The inclination of these systems is a major uncertainty in the determination of the mass of the compact object using optical spectroscopic methods. In this paper, we present a new method to constrain the inclination of X-ray binaries, which is based on the modeling of the polarization of X-rays photons produced by a compact source and scattered off the companion star. We describe our method and explore the potential of this technique in the specific case of the low-mass X-ray binary GS1826−238 observed by the Imaging X-ray Polarimetry Explorer observatory....
The launch of the IXPE telescope in late 2021 finally made polarization measurements in the 2–8 keV band a reality, more than 40 years after the pioneering observations of the OSO-8 satellite. In the first two years of operations, IXPE targeted more than 60 sources, including four magnetars, neutron stars with magnetic fields in the petaGauss range. In this paper we summarize the IXPE main findings and discuss their implications for the physics of ultra-magnetized neutron stars. Polarimetric observations confirmed theoretical predictions, according to which X-ray radiation from magnetar sources is highly polarized, up to ≈80%, the highest value detected so far. This provides an independent confirmation that magnetars are indeed endowed with a super-strong magnetic field and that the twisted magnetosphere scenario is the most likely explanation for their soft X-ray emission. Polarization measurements allowed us to probe the physical conditions of the star’s outermost layers, showing that the cooler surface regions are in a condensed state, with no atmosphere on top. Although no smoking-gun of vacuum QED effects was found, the phasedependent behavior of the polarization angle strongly hints that vacuum birefringence is indeed at work in magnetar magnetospheres....